Quality:
Competence:
Quality & competence:
Service
Examination and maintenance of lifebuoys
We carry out examination and maintenance of lifebuoys in accordance with MC SOLAS (LSA) requirements. An examination includes: marking inspection of life-saving appliances, external visual inspection, test for durability and buoyancy, as well as check for completeness of optional equipment (Lifebuoy self igniting light, lifebuoy line and self-activating smoke signal)

If necessary, we make replacement of components or rejection with the provision of a new product.
As soon as the examination is conducted we issue an original certificate of inspection, marked with the original label.
Examination and maintenance of lifejackets
We carry out examination and maintenance of rigid lifejackets in accordance with MC SOLAS (LSA). An examination includes: marking inspection, external visual inspection, test for durability and buoyancy, as well as check for completeness of optional equipment (Self igniting lights, reflecting materials and whistles)

If needed, we change components or make a rejection with the provision of a new product.
As a result of the examination we issue an original certificate of inspection, marked with the original label.

Maintenance and testing of immersion suits, antiexposure and thermal protection suits
We carry out maintenance and testing of immersion suits, antiexposure suits and thermal protection suits of all manufacturers in accordance with MC SOLAS (LSA).

As soon as the examination is conducted we issue an original certificate of inspection, while the product is marked with the original label.
Examination and maintenance of liferafts
We carry out the examination of the liferafts of both, throw-overboard and davit-launched types with SOLAS A-Pack, B-Pack, C-Pack. Our company uses only liferaft maintenance instructions provided by the manufacturer.

The examination of liferafts is carried out no more than once a year and consists of:
  1. technical condition test;
  2. inspection of the liferaft;
  3. mainatanance of the liferaft;
  4. technical condition check and maintenance of the liferaft deployment system;
  5. check of the equipment and emergency supply items;
  6. examination and maintanance of the container;
  7. examination of hydrostatic release units;
  8. replacing the weak link and the interchangeable element of the painter;
  9. packaging of the liferaft.

As a result of the examination, we issue an original certificate of check.
Examination of hydrostatic release units
Our company carries out technical examination of hydrostatic release unit with operating depth test (pneumatic test). Inspection of the hydrostatic release device is carried out after a year of operation (simultaneously with the inspection of the raft).

Following the test we provide a corresponding maintenance mark of HRU in the original passport of the raft.
Examination of inflatable, work, life and rescue boats
We carry out an examination and maintenance of inflatable, work, life and rescue boats in accordance with the MC SOLAS (LSA) requirements.

As a result of the examination, we issue an original verification certificate.
Examination and testing of hoisting equipment
The specialists of our company carry out a complex of works on the examination and testing of hoisting equipment.

As soon as the testing is completed we issue an original certificate for the tested devices.


Examination of pilot ladders and embarkation ladders
We carry out tests, maintanance, replacement of fasteners and components of pilot ladders and embarkation ladders of different lenths. As soon as the examination is conducted we issue an original certificate for the products that have passed the tests.
Examination of knotted lifelines
We carry out examination, tests, and maintanance of knotted lifelines with a length of 3 to 30 meters or more. Upon completion of the examination, we issue an original certificate of inspection.
Examination of the fireman's protective clothing
We carry out an examination of the fireman's protective clothing (heat protective suits) in accordance with the regulations SOLAS 74/88, as amended, MSC 98(73) IMO FSS Code, MSC.1/Circ. 1432, para. 5.5.

Following the test, we issue an original examination certificate for each heat protective suit.
Examination of protective clothing resistant to chemical attack
Our company carries out an examination of protective clothing resistant to chemical attack in accordance with the regulations SOLAS 74/88 (19.3.6.1).

Any examination and maintanance of protective clothing is carried out in accordance with the manufacturer's instructions of the given suit. The tightness of the suit is checked by supplying air into its cavity. If the pressure drop is insignificant within one minute, then the suit is mared as airtight. In case of a significant decrease in pressure, the suit is tested, eliminating the identified defects.

Based on the results of the examination, an original certificate is issued for each chemical protective suit.
Maintanance and check of EEBD’s (Emergency Escape Breathing Devices)
We carry out an examination of emergency escape breathing devices (self-rescuers) on compressed air of continuous flow and self-rescuers with chemically bound oxygen and pendulum breathing scheme.

The self-rescuer is checked once a year in accordance with the manufacturer's instructions.

Upon examination, an original certificate for each device is issued.
Examination and maintenance of a self-contained breathing apparatus
Our company carries out examination and maintenance of self-contained breathing apparatus. The breathing apparatus is dismantled by specialists for inspection and cleaning. Found faults are eliminated. We charge the assembled apparatus with compressed air and check for serviceability.

Following the check, we issue an original examination certificate for a self-contained breathing apparatus.
Examination of suction, pressure-suction, pressure fire hoses
We carry out an examination and maintenance of suction, pressure-suction, pressure fire hoses. Upon completion of the examination, we issue an original examination certificate for each fire hose. Fire hoses are visually inspected to determine the presence of markings, possible external and internal damage or defects. We check the outer and inner surfaces of fire hoses, including the fire hose couplings and their joints for discoloration, stains, cuts, punctures, deformations, breaks, cracks, etc. Based on the results of such an inspection, we decide on the further running of the hoses or the need for their testing and maintanance.
Examination and maintenance of fire hose cabinets
We carry out an examination and maintenance of fire hose cabinets.

Inspection and maintenance of the fire hose cabinets is carried out once a year. The fire hose cabinet is checked with a fully unrolled hose, which is under pressure. If the fire hose has signs of a limiting state, we make rejection with replacement by the new unit.

All defects are eliminated as soon as possible to get all fire-fighting equipment back to a stanby condition.
Maintanance and tests of stationary CO2 fire-extinguishing systems
We carry out examinatoin, tests and maintanance of stationary CO2 fire-extinguishing systems of high and low-pressure. Upon completion of the check, we issue an original examination certificate.

All checks dealing with stationary CO2 fire-extinguishing systems are carried out in accordance with manufacturer's instructions and regulattory documents MO MSC.1/Circ.1318 and MSC/ 1/Circ. 1432.

Examination and maintenance of fire extinguishers
For many years, our company has been successfully conducting examination and maintenance of carbon dioxide, powder, mechanical foam fire extinguishers. Upon completion of the examination, we issue an original examination certificate.

We competently perform such services as:
  • Check (technical diagnostics) of carbon dioxide BC type, dry powder ABC type and mechanical foam AB type fire extinguishers;
  • Maintenance and replacement (on fault detection) of spare parts;
  • Hydraulic testing of cylinders;
  • Washing and drying of cylinders;
  • Painting of cylinders;
  • Recharge of fire extinguishers;
  • Charging of pilot cylinders BVD 80 - 200;
  • Rejection and disposal of cylinders;

Upon completion of the examination, we issue an original examination certificate.
Inspection of fire extinguishing systems by water spraying and water mist
We carry out maintenance and testing of stationary fire extinguishing systems by water spraying and water mist. Upon completion of the inspection, we issue an original examinatoin certificate.

Maintenance and inspection intervals are carried out in accordance with the regulations:
1. MSC/ 1/Circ. 1432
2. SOLAS reg.II-2/14.2.2
3. MSC./Circ.1516

Maintanance of fire-fighter's belts, safety belts and ropes
We provide services for maintenance, examination and check of fire-fighter's belts, safety belts and safety ropes. Also, we carry out maintanance and replacement on fault detection.

After the tests are completed, we issue an original examination certificate.
Maintanance and inspection of dry powder fire extinguishing system
We carry out maintenance and testing of stationary dry powder fire extinguishing systems. All maintenance and inspection work is carried out in accordance with MSC/ 1/Circ. 1432. Upon completion of the inspection, we issue an original examination certificate.

Maintanance and inspection of stationary foam extinguishing systems
We carry out full inspection and maintanance of stationary foam extinguishing systems. All maintenance and inspection work is carried out in accordance with the manufacturer's standards and technological instructions. As soon as the inspection is over, we issue an original examination certificate.

Maintenance and inspection of stationary aerosol fire extinguishing systems
We carry out maintenance and inspection of stationary aerosol fire extinguishing systems.

The vessel's volumetric aerosol fire extinguishing system has a number of advantages over other systems: the weight of the system is 10-15% less than other similar gas system, the cost is 50-60% lower, it is non-toxic and the system can be installed without removal the ship from operation. The system consists of fire-extinguishing aerosol generators, control and signal panel, intermediate relay board, electrical circuits and light and sound alarms. All maintenance and inspection work is carried out in accordance with MSC/ 1/Circ. 1432, and the IMO FSS Code.
Pressure vessels examination and maintenance
We carry out examination and maintenance of pressure vessels.

The examination of pressure vessels includes:
  • Inspection of the outer and inner surfaces of the cylinders (pressure vessels);
  • Hydraulic test;

Repair and maintenance of radio navigation equipment
Our company performs repair and maintenance of radio navigation equipment in accordance with the requirements of regulation IV / 15 of the SOLAS-74 Convention as amended, IMO resolution A.702 (17) and the requirements of classification societies.

  1. GMDSS equipment in accordance with the requirements of rules 15 of Chapter IV of SOLAS-74;
  2. Automatic Identification System (AIS);
  3. EPIRB and DSC units using equipment and software from manufacturers.
  4. Radar testing
  5. Deviation, repair and maintenance of compasses and gyrocompasses
  6. Maintenance and repair of radars, echo sounders, logs, portable radios


Repair and maintenance of precision mechanics:
Our company offers repair and maintenance of navigation equipment in accordance with the requirements of classification societies.

Services

We have created a regional network of service stations in Ukraine! Our company is constantly evolving to offer you a wide range of quality marine and fire services available in all parts of Ukraine.